3.1. Air Supply
3.1.1. Ensure tool valve (or trigger) is in the "off" position before connecting to the air supply.
3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.
3.1.3. WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the
tool. Too high an air pressure and unclean air will shorten the product life due to excessive
wear, and may be dangerous causing damage and/or personal injury.
3.1.4. Drain the air tank daily. Water in the air line will damage the tool.
3.1.5. Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig.1.
3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8
metres). The minimum hose diameter should be 1/4” I.D. and fittings must have the same
inside dimensions.
3.1.7. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain
that all connections are secure.
3.2. Couplings.
Vibration may cause failure if a quick change coupling is connected directly to the tool. To
overcome this, connect a leader hose to the tool. A quick change coupling may then be used
to connect the leader hose to the air line recoil hose. See fig.1 & 2.
WARNING! Ensure you read, understand and apply safety instructions before use.
Note: Numbers in brackets refer to item numbers in the parts diagram.
4.1. Flux chipper
4.1.1. Fit the spring (4) onto the rounded end of the chisel (15) before fitting the chisel into the
barrel sleeve (12).
4.1.2. Fit the nut (20) over the sharpened end of the chisel (15), screw it onto the barrel sleeve
(12) and tighten.
4.1.3. Connect the tool to the air hose as in chapter 3.
4.1.4. To start the tool, depress the throttle lever.
4.2. Needle scaler
4.2.1. To use as a needle scaler, unscrew the nut (20) and remove the chisel (15) and spring (4).
4.2.2. Fit the needle driver (14) and ensure the spring (18) is located in the needle tube (19).
4.2.3. Ensure the needle holder (17) is fitted with needles (16) such that the heads of the needles
do not protrude above the surface of the needle holder.
4.2.4. Fit the needle holder (17) into the needle tube (19), screw the needle tube (19) onto the
barrel sleeve (12) and tighten.
4.2.5. To start the tool, depress the throttle lever.
DO NOT allow the tool to free run for an extended period of time as this will shorten its life.
fig.1